The CA 9000 Professional breathalyzer combines an elegant design with modern measurement technology and an electrochemical (fuel cell) sensor for high accuracy and repeatable results. It offers a clear digital display, storage of recent measurements, and a range of protective functions for safe and reliable use.
Electrochemical sensor for accurate measurement
The modern electrochemical (fuel cell) sensor delivers high accuracy and repeatability of results. Readings are clearly shown on the digital display.
Measurement memory and smart control functions
The breathalyzer stores up to 10 most recent results and uses proper operation checks before and after the test. It also includes a calibration reminder and a counter of performed tests.
Safe in-car use thanks to protections and temperature control
A built-in airflow sensor and protective system help protect the measuring chamber during an incorrect test. Temperature control also prevents testing outside the operating range, reducing errors and protecting the sensor.
The CA 9000 Professional is a top-tier electrochemical alcohol tester designed for users who want accurate measurements and confidence before driving. It displays digital results in the 0.00–4.00 range with a resolution of two decimal places and stores up to 10 most recent measurements in memory.
For maximum reliability, it is equipped with functions that protect the measuring chamber and monitor the correct course of the test. A calibration reminder and temperature control are also included to prevent testing outside the safe operating range.
Main advantages:
- Electrochemical sensor for accurate and stable results
- Airflow sensor and measuring chamber protection in case of incorrect test procedure
- Proper operation check of the device before and after each measurement
- Temperature control module to reduce errors and extend sensor life
- Automatic power-off to save battery and low-voltage indication
Specifications
- Sensor type
- Electrochemical (fuel cell)
- Measurement range
- 0.00–4.00
- Display resolution
- 2 decimal places
- Memory
- Up to 10 most recent results
- Airflow sensor
- Yes
- Measuring chamber protection
- Yes, against damage due to an incorrectly performed test
- Analyzer self-check
- Yes, before and after each measurement
- Temperature control module
- Yes, blocks measurement outside the operating temperature range
- Test counter
- Yes
- Calibration reminder
- Yes
- Power supply
- 2× AAA (1.5 V)
- Low battery indication
- Yes
- Automatic power-off
- After 20 s of inactivity or 30 s after a measurement is taken