FNIRSI FNB48P BT is an advanced USB port tester for accurate measurement of voltage, current, and power during charging. It supports USB-A, USB-C, and Micro USB, recognizes common fast-charging protocols, and thanks to Bluetooth enables convenient analysis and data archiving in the app and on a PC. A rugged metal housing, clear display, and cable diagnostic features make it a reliable tool for service work and demanding users.

FNIRSI FNB48P BT is a universal USB measuring and diagnostic tool that helps you quickly verify the behavior of chargers, cables, and powered devices. With support for multiple ports (USB-A/USB-C/Micro USB) and high current up to 6.5 A, you can easily measure both standard and more demanding charging scenarios, including USB Power Delivery.

The tester detects and verifies popular fast-charging standards (e.g., QC, PD, AFC, FCP/SCP, VOOC/DASH/WARP, SuperVOOC, etc.) and also offers smart cable diagnostics—including PD e-marker detection and cable internal resistance measurement to assess losses and quality.

The large 1.77" HD display shows key parameters and graphs (voltage/current, logging, power ripple), and the gravity sensor enables automatic screen rotation for comfortable reading. Logging of up to 10 data sets and battery capacity calculations make long-term testing easier; Bluetooth and the PC interface expand options for analysis and saving results.

  • Measurement range up to 24 V and 6.5 A (max. 156 W)
  • Fast-charging support and compatibility verification
  • Cable diagnostics (PD e-marker, resistance measurement)
  • Graph modes and offline logging
  • CNC metal housing for high durability

Specifications

Manufacturer
FNIRSI
Model
FNB48P BT
Measured voltage
Range 4–24 V; resolution 0.00001 V; accuracy ± (0.2% + 2)
Measured current
Range 0–6.5 A; resolution 0.00001 A; accuracy ± (0.5% + 2)
Measured power
Range 0–156 W; resolution 0.00001 W; accuracy ± (0.5% + 2)
Equivalent load resistance
Range 0–9999.9 Ω; resolution 0.0001 Ω; accuracy ± (0.5% + 2)
D+ / D- line voltage
Range 0–3.3 V; resolution 0.001 V; accuracy ± (1.0% + 2)
Device temperature
Resolution 1 °C; accuracy ± (1.2% + 3)
Capacity
Range 0–9999.99 Ah; resolution 0.00001 Ah
Consumed energy
Range 0–9999.99 Wh; resolution 0.00001 Wh
Conductor resistance
Range 0–9999.9 Ω; resolution 0.0001 Ω
Operating time
Max. 99 days 23 h 59 min 59 s; resolution 1 s
Data logging time
Max. 999 h 59 min 59 s; resolution 1 s