LAN cable UTP 100 Mb/s 305 m CCA, red

846202-1
€37.90
On the road, at your place 6. 10. 2025
UTP LAN cable 305 m, 100 Mb/s, CCA, AWG 24, red RAL3017. Cost-effective solution for short runs, meter markings, unshielded, up to 100 MHz.

LAN cable UTP 100 Mb/s 305 m CCA, red

846202-1
UTP LAN cable 305 m, 100 Mb/s, CCA, AWG 24, red RAL3017. Cost-effective solution for short runs, meter markings, unshielded, up to 100 MHz.
€37.90
On the road, at your place 6. 10. 2025
Reliable network cable for basic data cabling over shorter distances. Offers speeds up to 100 Mb/s, unshielded U/UTP design, length of 305 m, CCA conductors (copper-clad aluminum), and a distinctive red RAL3017 color. Suitable for cost-effective installations without a Fluke certification requirement.

This UTP cable is an ideal choice for budget-friendly, less demanding applications. Thanks to its CCA (copper-clad aluminum) construction and solid AWG 24 conductors, it is suitable for short runs where stable 100 Mb/s connectivity up to 100 MHz is required. The red RAL3017 finish helps with route identification in cabinets and cable trays.

Supplied in a carton with meter markings every 1 m for precise measuring. The cable features a PVC jacket with a 5.0 mm diameter and HDPE conductor insulation, ensuring good workability and basic mechanical protection in indoor installations.

  • Performance and compatibility: up to 100 Mb/s, operating frequency up to 100 MHz, recommended for segments of approx. 10 m.
  • Construction: U/UTP (unshielded), solid AWG 24 (4 pairs), CCA conductors for cost savings.
  • Easy installation: meter markings, carton pull-out from the box, red color for quick identification.
  • Intended use: installations without Fluke certification requirements (EN 50173), short patch runs, low-cost cabling.

Specifications

Cable type
LAN U/UTP (unshielded)
Data rate
100 Mb/s
Pack length
305 m (carton)
Conductor
CCA, solid
AWG
24 (4×2×0.5 mm)
Jacket diameter
5.0 mm (PVC)
Conductor insulation
HDPE, 0.93 mm
Color
Red RAL3017
Operating frequency
up to 100 MHz
Meter marking
yes, every 1 m
Conductor resistance (max.)
60–90 Ω / 305 m
Insulation resistance (min.)
5000 MΩ·km
Pair-to-ground capacitance
< 330 pF / 100 m
Characteristic impedance
100 Ω (±15)
Storage/transport temperature
0 to +60 °C
Operating temperature
−20 to +70 °C
Recommended segment length
up to 10 m (maximum reach 100–120 m depending on conditions)
Standard/certification
Intended for installations without Fluke certification requirement (EN 50173)
€37.90